Buy DIN EN ISO PAINTS AND VARNISHES – DETERMINATION OF RESISTANCE TO NEUTRAL SALT SPRAY (FOG) from SAI. DIN EN ISO Paints and varnishes – Determination of resistance to neutral salt spray (fog) (ISO ); German version EN ISO Draft standard [WITHDRAWN] DIN ISO – Draft. Paints and varnishes – Determination of resistance to neutral salt spray (fog) (ISO.

Author: JoJorn Brakree
Country: Ecuador
Language: English (Spanish)
Genre: Automotive
Published (Last): 18 September 2018
Pages: 118
PDF File Size: 7.30 Mb
ePub File Size: 2.1 Mb
ISBN: 743-6-64112-263-5
Downloads: 14042
Price: Free* [*Free Regsitration Required]
Uploader: Shalrajas

Nevertheless, the method described gives a means of checking that the comparative quality of a metallic material, with een without corrosion protection, is maintained. You may also wish to consider the prohesion test as a possible alternative. The temperature shall be measured at least mm from the walls. If you have smaller samples you can fix them to x 75 mm panels provided the overall thickness does not exceed 5 mm. The size and shape of the cabinet shall be such that the collection rate of solution in the cabinet is within the limits specified in Table?

Akzo unveils new strategy to accelerate growth and value creation 26th April Read more.

CORROTHERM 610/400

Unless otherwise specified, the back and edges of the panel shall be coated with the coating system under test. Then remove the corrosion products by repetitive cleaning as described in ISO BS EN and IEC are alternative names for the same method which is intended to measure how well components or equipment can withstand a salt-laden atmosphere.

The isi duration shall be 48 h. Duration of the test. Suitable funnels have a diameter of ?

That’s the only way to know for sure. Assessment of degree of cracking ISO Evonik opens coatings laboratory in Turkey 8th March Read more. Make any necessary correction by adding glacial acetic acid or sodium hydroxide of analytical grade. Possible changes in pH may result from loss of carbon dioxide from the solution when it is sprayed. Such changes can be avoided by reducing the carbon dioxide content of the solution by, for example, heating it to a temperature above 35?

  ESTREPTOCOCOSIS PORCINA PDF

Check the pH using electrometric measurement or in routine checks, with a short-range pH paper, which can be read in increments or 0,3 pH units or less. After cleaning, rinse the reference specimens with fresh solvent and then dry them. Preference shall be given to apparatus that has a means for properly dealing with fog after the test, prior to releasing it from the building for environmental conservation, and for drawing water prior to discharging it to the drainage system.

The salt spray tests are particularly useful for detecting discontinuities, such as pores and other defects in certain metallic, organic, anodic oxide and conversion coatings. Assessment of degree of blistering ISO? It is often not possible to use results gained from salt spray testing as a comparative guide to the long-term behaviour of different coating systems, as the corrosion stress during these tests differs significantly from the corrosion stresses encountered in practice.

This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by Novemberand conflicting national standards shall be withdrawn at the latest by November The upper parts of the cabinet shall be designed so that drops of sprayed solution formed on its surface do not fall on the specimens being tested.

  INTERPRETACION UROANALISIS PDF

This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by Januaryand conflicting national standards shall be withdrawn at the latest by January Care shall be taken that specimens are not recontaminated after cleaning by careless handling.

The quantity of liquid paint we need depends on the method of application. English price group 13 www. The test procedure shall 72533 be carried out as soon as possible.

Equivalence between ASTM B-117 vs. ISO 9227 NSS

Characteristics considered in evaluating the resistance of the test coating and method s of inspection used. Assessment of degree of flaking ISO? The method differs from the standard salt spray tests in that the salt solution used in the prohesion test is much more dilute and the panels are not exposed to it continuously. The test duration shall be 48?

CORROTHERM / — ERICHSEN

The level isl the salt solution in the salt reservoir shall be maintained automatically to ensure uniform spray delivery throughout the test. These tests are designed to evaluate how well the surface coatings protect substrates from corrosion.

We can test different size samples if required with maximum dimensions of x x mm If you wish, we can prepare the test panels. The quantity of liquid paint we needs depends on the method of application. The methods all involve exposure to high humidity combined with a limited choice of temperatures.