General Dwelling Calculation Method (NEC ). By Warren Goodrich. General If 3 or less appliances, then enter at percent. If there are four, or more. Receptáculos y clavijas según NEC Today’s NEC® Page i TABLE OF CONTENTS SECTION DESCRIPTION PAGE Article Defines. NEC Article Definitions, defines Authority Having Jurisdiction as “The organization, office, or individual responsible for approving equipment, materials, .

Author: Vogami Arajinn
Country: Swaziland
Language: English (Spanish)
Genre: Career
Published (Last): 4 July 2005
Pages: 229
PDF File Size: 6.45 Mb
ePub File Size: 3.79 Mb
ISBN: 772-3-95619-238-9
Downloads: 68335
Price: Free* [*Free Regsitration Required]
Uploader: Kazrar

Some Utility companies require you to furnish your meter base. The six maximum number of breakers may be either single pole or double pole breakers as long as it only takes six sweeps of the hand to just off all the main 100 forms.

General Dwelling Calculation Method (NEC ) – Self Help and More

Then refer to nec article This will now be your adjusted demand load, concerning all of the fastened-in-place appliances va.

The conductors serving outside receptacles exposed to physical damage must be protected by the proper minimum nipple size required according to the size of the conductor being protected and the type of nipple being used. PVC is bec2002 exempt from the plastic bushing requirement for conductors 4 awg or larger. This use of NEC Table The maximum allowable time for any type of temporary wiring are as follows; 90 DAYS on non construction type projects.

A The number of breakers counted as main disconnects must not exceed 6 sweeps of the hand.

General Dwelling Calculation Method (NEC 2002)

You must use a service rated panel equal to or larger than the demand load calculated for your project as required by NEC Article and NEC Article This document is based on the national electrical code and is designed to give you an option, as a self-help, that should pass minimum code requirements. Absolute minimum grounding electrode conductor size is a 8 copper for amp or less and 6 copper for more than amp. Apply general lighting demand factor to the total of the above 3 steps.

The article is for nec202 purposes only and is not a substitute for professional advice. The requirements of other receptacles stated in NEC Article A using a normal receptacle mounting yoke.

  ENFERMEDAD FIBROQUISTICA DE LA MAMA PDF

The receptacles on the temporary must have a weathershield mounted over the nfc2002. If you use a type service panel with more than two [three or more] circuits in the box, you must use a minimum rating of nec20002 amps, weatherproof service rated panel.

All volt rated receptacles rated in amps 15, 20, or 30 that are installed on a temporary service pole or installed for use as temporary wiring must be GFCI protected NEC Article The minimum size wire to your receptacles, through your offset nipple, from your over-current device [breaker or fuse], is 14 awg using a 15 amp maximum size overcurrent device.

No less is required of a temporary pole service than a normal main dwelling service only smaller in amp rating and weatherproof. You must use the 60 degree column found in NEC Table If your service panel main over-current device size is amps in a residential setting, you must use a feeder rated no less than a amp rated conductor, from the transformer, through to the main lugs of the service panel, or the 1000 of your main over-current device depending on the service rated panel style that you plan to use.

All the above was added together to obtain your neutral service conductor demand load calculation of 18, volt amps.

Suggested Wiring Procedures for an Overhead Temporary Service Pole (NEC 2002)

Any form of receptacle exposed to the weather must be with a weather shield. Search for great deals on electrical from local home improvement companies and contractors. D The maximum size wire to your receptacles, through your offset nipple, from your overcurrent device [breaker or fuse], is 12 awg using a 20 amp maximum size overcurrent device.

We might want to compare the conductor ampacity ratings found in NEC Table An example of an overhead meter base showing line [power into meter base] and load [power out of meter base to your panel] may be viewed by clicking on the picture icon to the left.

Some Utility companies will furnish that meter base for your temporary. In this case your calculated demand load dictating your main service rated panel required a minimum main service rated panel size of amps.

  LENZE 8201 PDF

When you come out of the bottom of the disconnect or panel, you will find your bossed [treaded] receptacle box conduit hole, laying offset from the hole at the bottom of your disconnect or panel box. One example of an overhead temporary service may be viewed by clicking on the picture icon to the left. B This type of self-grounding receptacle is commonly used on metal conduit wiring style often found on commercial project where no grounding conductor is ran, but instead this wiring style is using the conduit as the grounding path.

Suggested Wiring Procedures for an Overhead Temporary Service Pole (NEC ) – Self Help and More

Accepted practice will lead you to Sch 40 PVC due to a cost factor. Find a Pre-Screened Electrician. B Allows that the main service overcurrent device be adjusted up to the next larger overcurrent device size if the conductor ampacity does not meet the overcurrent device size listed in If installing a grounding electrode conductor to a made electrode the maximum grounding electrode conductor size required is a 6 awg copper conductor NEC Article This is where you really should make those two contacts both the AHJ [local Electrical Inspector] and your serving Utility Company for specialized local rules.

Check the support requirements of the style and type of conduits you are using.

If the conductor required is smaller than a 1 AWG. Add from here down when finding the total demand load of the dwelling. Find the largest motor involved, and multiply that motor’s full load current flc by 25 percent, and enter that figure. nec20002

You must not use an aluminum grounding electrode in direct contact with the earth. This weathershield might be clear or opaque.

Any other type receptacle other than volt 15, 20, 30 amp receptacles, no matter what amp or voltage rating, must also be GFCI protected or you must have a documented, recorded record showing the tests were done before initial use and every 3 months thereafter.